ZX2
Sensor de medición láser estable, fácil y asequible
Alta precisión y estabilidad de medición, a un precio asequible. El nuevo sensor láser ZX2 ofrece el mejor rendimiento de su clase para aportar precisión y velocidad a todas las aplicaciones de desplazamiento lineal. Con el uso de un sensor de imagen avanzado CMOS HSDR se obtiene gran estabilidad de medición, incluso en las superficies más difíciles.
- Configuración sencilla
- Precisión: 1,5 – 5 µm
- Cualquier superficie
- Alta velocidad: 30 µs
Especificaciones y modelos disponibles
Ordering information
Sensor heads
|
||||
|
||||
|
Amplifier units
Accessories (order separately)
These are not included with the sensor head or amplifier unit.
Calculating unit
Sensor head extension cables 1
Mounting brackets
Specifications
Diffuse reflective Sensor Heads
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1 mW max. |
||||
Beam size1 |
||||
Resolution2 |
||||
Linearity3 |
||||
Temperature characteristic4 |
||||
Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) |
||||
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes. each in X,Y,and Z directions |
||||
300 m/s 2 3 times each in six directions (up/down,left/right,forward/backward) |
||||
Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Cable: PVC |
||||
Instruction sheet, Ferrite core, Laser warning label (English), FDA certification label |
Regular-reflective Sensor Heads
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24 mW max. EN class 1, FDA class I |
|
Beam size2 |
|
Resolution3 |
|
Linearity4 |
|
Temperature characteristic5 |
|
Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) |
|
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes. each in X,Y,and Z directions |
|
300 m/s 2 3 times each in six directions (up/down,left/right,forward/backward) |
|
Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Cable: PVC |
|
Instruction sheet, Ferrite core, Laser warning label (English) |
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
Amplifier units
Measurement period6 |
||
60 µs, 120 µs, 240 µs, 500 µs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms, 128 ms, 250 ms, 500 ms |
||
Analog output7 |
4 to 20 mA, Max. load resistance: 300Ω, ±5VDC or 1 to 5 VDC, Output impedance: 100Ω |
|
NPN open-collector outputs, 30 VDC, 50 mA max.(residual voltage: 1 V max. for load current 10 mA max.,2 V max. for load current above 10 mA) |
PNP open-collector outputs, 30 VDC, 50 mA max.(residual voltage: 1 V max. for load current 10 mA max., 2 V max. for load current above 10 mA) |
|
Laser OFF input, zero reset input, timing input, reset input, bank input |
ON: Short-circuited with 0-V terminal or 1.5 V or less |
ON: Supply voltage short-circuited or supply voltage within 1.5 V |
Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/clamp switch, (A-B)calculations8, thickness calculation3, mutual interference prevention3, laser deterioration detection, bank function (4 banks) |
||
Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main display (red), 11-segmentsub-display (orange), laser ON (green), zero reset (green), enable (green), menu (green), HIGH threshold (orange), LOW threshold (orange) |
||
3,000 mW max. with power supply voltage of 30 VDC and power supply current of 100 mA (with Sensor connected) |
||
Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) |
||
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X,Y,and Z directions |
||
300 m/s 2 3 times each in six directions (up/down,left/right,forward/backward) |
||
Case: PBT(polybutylene terephtahalate), Cover: Polycarbonate, Display: Acrylic resin, Button: Polyacetal, Cable: PVC |
||
Calculating unit
2. Beam size: Defined as 1/e 2 (13.5%) of the central intensity at the smallest value of diameter for the measurement range (typical value) False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
3.
Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models: white ceramic object, regular-reflective models: 1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.)
Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
4. Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’ s standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50 (L): 20mm)
5. Temperature characteristic: Value for the case the space between the sensor head and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
*5 These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective models under EN 606825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has been completed for diffuse-reflective models and is scheduled for regular-reflective models.
2. Beam size: Defined as 1/e 2 (13.5%) of the central intensity at the smallest value of diameter for the measurement range (typical value) False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
3.
Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models: white ceramic object, regular-reflective models: 1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.)
Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
4. Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’ s standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50 (L): 20mm)
5. Temperature characteristic: Value for the case the space between the sensor head and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
*5 These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective models under EN 606825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has been completed for diffuse-reflective models and is scheduled for regular-reflective models.
¿En qué podemos ayudarle?
Si tiene alguna duda o necesita información sobre un presupuesto, póngase en contacto con nosotros o envíe una solicitud.
Contacten conmigo ZX2
Gracias por enviarnos su solicitud. Le responderemos lo antes posible.
Tenemos dificultades técnicas. Su formulario no ha sido enviado. Porfavor, acepte nuestras disculpas e inténtelo de nuevo más tarde.\ Detalle: [details]
DownloadPresupuesto para ZX2
A través de este formulario puede solicitar cotización del producto escogido. Por favor, cumplimente todos los campos marcados con *. Sus datos personales serán tratados con la máxima confidencialidad.
Gracias por la cotización solicitada. Le enviaremos la información solicitada lo antes posible.
Tenemos dificultades técnicas. Su formulario no ha sido enviado. Porfavor, acepte nuestras disculpas e inténtelo de nuevo más tarde.\ Detalle: [details]
DownloadCaracterísticas
Sensor de imagen CMOS HSDR
El ZX2 utiliza un sensor de imagen CMOS HSDR ( High Speed & Dynamic Range, alta velocidad y alto rango dinámico) recientemente desarrollado. Ofrece medidas estables en superficies desde altamente absorbentes hasta altamente reflectantes sin perder precisión. El ZX2 controla de forma continua el nivel de luz recibido y ajusta la salida del diodo láser para compensarla, todo en un ciclo de 60 μs.
Configuración sencilla
Configuración sencilla del ZX2. El ZX2 elimina la necesidad de realizar una configuración compleja mediante ajustes de parámetros prolongados. Se utiliza un botón inteligente para configurar el sensor al definir el tipo de superficie de medida.
- Un tipo de superficie
- Varios tipos de superficies
- Superficies altamente reflectantes
Aplicaciones
Aplicaciones de detección de doble hoja
La medición de alta precisión y la capacidad de afrontar varios tipos de superficies permite el uso de ZX2 para la inspección de doble hoja.
Aplicación de referencia de posición
Las mediciones lineales precisas se pueden realizar a gran velocidad, lo que permite el uso de ZX2 para aplicaciones de referencia de posición de alta velocidad.
Aplicación de medida del grosor
La medida del grosor se realiza de forma sencilla en el ZX2 mediante la unidad de cálculo. Se pueden obtener medidas precisas del grosor incluso en superficies altamente reflectantes.
Medida de la distorsión
Con varias unidades ZX2 se puede observar la distorsión o deformación de los componentes. Incluso si varía la temperatura o la superficie de medida, se pueden obtener medidas estables.