E2E-IL
- Librería CAD
- Datos de piezas EPLAN
- E2E-_-IL_ IO-Link Proximity Sensors, Standard Datasheet
Thank you for downloading the E2E-_-IL_ IO-Link Proximity Sensors, Standard Datasheet
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

-
Predictive Maintenance with IO-Link (Demo)
-
Predictive Maintenance with IO-Link (Demo)
Bringing predictive maintenance to your production line with OMRON IO-Link Compliant Solutions.
00:48
-
Sensores de proximidad estándar IO-Link: una innovadora solución para los problemas de las plantas de fabricación industriales.
Sensores de proximidad estándar IO-Link: una innovadora solución para los problemas de las plantas de fabricación industriales.
- Los tiempos de inactividad se pueden reducir mediante funciones de diagnóstico internas
- El fallo repentino se puede reducir mediante una notificación, si los objetos están demasiado lejos o demasiado cerca
- Las operaciones de mantenimiento son más eficientes mediante la identificación de cada sensor a través de la red de IO-Link
- El funcionamiento programable del sensor reduce el número de modelos necesarios
Ordering information
DC 3-wire IO-Link models
![]() |
||||||||
Specifications
DC 3-wire IO-Link models (E2E-X_B4-IL_)
Set distance1 |
||||
Response frequency2 |
||||
Indicators1 |
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability indicator (green, lit) In the IO-Link mode: Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
|||
IEC 60529 IP67, in-house standards: oil-resistant3 |
||||
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) |
||||
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, and initial reset |
||||
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) |
||||

In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.)
Please contact your OMRON sales representative regarding assignment of data.
In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.)
Please contact your OMRON sales representative regarding assignment of data.
XS2

XS3

XS5C/XS5G

Y92E-S_PP

Catálogos
Mostrar todo catálogosGuía de conexión
Mostrar todo guía de conexiónArchivos de descripción del dispositivo
Mostrar todo archivos de descripción del dispositivoDatasheets
Manuales
Mostrar todo manualesSuscripción a novedades
Boletines sobre avances tecnológicos, soluciones y servicios, directamente en su bandeja de entrada.
Gracias por suscribirse a las eNews de Omron. En breve, recibirá un e-mail nuestro. Este e-mail contiene un link para activar su suscripción al servicio de newsletter de Omron. Usamos este méto para asegurarnos de que nadie puede manipular su e-mail y para cumplir con las condiciones legales de protección de datos.
Tenemos dificultades técnicas. Su formulario no ha sido enviado. Porfavor, acepte nuestras disculpas e inténtelo de nuevo más tarde.\ Detalle: [details]
DownloadDocumentación de productos
Descarga datasheets, manuales y catálogos.
Explore el centro de descargasCursos de formación
Fórmese con nuestros mejores ingenieros. Para principiantes o usuarios avanzados.
Ver cursos de formación